ELASTIC COUPLING SPIN

The primary application of the flexible detachable couplings of the SPIN type is to connect the electric or hydraulic drive motor to the shaft of the driven equipment. They are recommended wherever it is difficult to disassemble the motor.

Powiększ ELASTIC COUPLING SPIN

A Type "U“ insert can be replaced without disassembling the engine from the drive system. Type SPIN couplings should not be used in drive systems with very large dynamic torque changes due to their simple construction (only the elastic element of Type 'U' is used).

OPERATING CONDITIONS

SPIN type couplings tolerate angular misalignment between the motor shafts and the driven equipment well but require more precise radial alignment. They can be used in machinery intended for operation in underground mines of methane explosion classes a, b, c, and coal dust explosion classes A and B, provided that machines equipped with these couplings have undergone EC type-examination.

APPLICATION

The primary application of elastic SPIN type couplings is to connect an electric or hydraulic drive motor to a shaft of the driven equipment, such as gearboxes in belt and scraper conveyors, compressors, pumps, fans, and other devices. It is recommended to use them in situations where disassembling the motor is difficult. The Type U insert can be replaced without removing the motor from the drive system."

TECHNICAL DATA

Couplingtype MOJ (mechanical size)   4 8 16 32 50 75
Transmitted power (1500 rpm) kW 55 100-132 200 315 500 750
Maximum rotational speed min -1 3000 3000 3000 3000 1500 1500
Rated torque Nm 350 852 1283 2020 3000 4000
Acceleration torque Nm 875 2129 3207 5051 8000 10000

Angular deformation of the couplingat rated torque
for elastomer hardness 90°Sh φN

(°) ok. 5 ok. 6 ok. 6,5 ok. 7 ok. 5 ok. 5
Axial assembly deviation ΔP
(for the construction site)
mm 1–1,5 1–1,5 1–1,5 1–1,5 1–1,5 1–1,5
Installation offset, radial offset ΔPr mm 1,5 1,5 1,5 1,5 1,5 1,5

Permissible inclination angle of the couplinghalves axis
in continuous operation ΔKw

(°) 1,5 1,5 1,5 1 1 1